Donath-Landsteiner Test

Label Mnemonic: DONATH
Epic code: LAB9892
Downtime form: Doctor/Provider Orders - Pathology Core and Specialty Care Nursery
Commercial Mailout Laboratory
6240-8 RCP
356-8593
Specimen(s):
Serum
Specimen Instructions:

Place the tube(s) into a ziplock bag prior to placing in the provided insulated sample store container.

Collection Medium:
Red top tube 5 mL (Clot Activator)
Minimum:

One full red top tube. Dedicated specimen required.

Rejection Criteria:

Specimen must be labeled with the patient's first and last name and medical record number. Specimens will be rejected if information is not on the label when received. Serum separator tubes (SST).

Delivery Instructions:

Deliver to DeGowin immediately after collection.

Turn Around Time:

1–3 days upon receipt at the reference laboratory.

Reference Range:

See interpretation

Interpretive Data:

Use to diagnose paroxysmal cold hemoglobinuria. The presence of other red blood cell antibodies may interfere with testing, leading to inconclusive results.


This is the diagnostic test for paroxysmal cold hemoglobinuria (PCH), which is the rarest form of autoimmune hemolytic anemia. PCH is most commonly encountered as a transient form in young children secondary to viral infection. On rare occasions, PCH associated with syphilis or the idiopathic chronic form is seen in older persons.

Comments:

Contact the Blood Bank to obtain an insulated sample storage container. (319) 356-2561.

Methodology:

Hemolysis

CPT Code:
86940, 86941