Phospholipase A2 Receptor (PLA2R) Antibody, IgG with Reflex to Titer
Label Mnemonic: | PLA2R |
Epic code: | LAB8739 |
Downtime form: | Doctor/Provider Orders - Pathology Core and Specialty Care Nursery |
Commercial Mailout Laboratory
6240-8 RCP
356-8593
6240-8 RCP
356-8593
Specimen(s):
Serum
Collection Medium:
![]() |
Red top tube 5 mL (Clot Activator) |
Minimum:
Preferred Minimum: 1.0 mL serum in red top tube
Absolute Minimum: 0.2 mL serum in red top tube
Absolute Minimum: 0.2 mL serum in red top tube
Rejection Criteria:
Hemolyzed, hyperlipemic, icteric, heat-treated or contaminated.
Turn Around
Time:
1-8 days upon receipt at reference laboratory
Reference Range:
Less than 1:10
Interpretive Data:
A positive result (1:10 or greater) for phospholipase A2 receptor
antibody, IgG, in conjunction with other laboratory and clinical
findings, supports a diagnosis of primary membranous
glomerulonephritis (pMGN).
Comments:
This test aids in the differential diagnosis of membranous
glomerulonephritis (MGN) or nephrotic syndrome of unknown
etiology.
Note: If Phospholipase A2 Receptor Antibody, IgG is positive, then a Phospholipase Receptor A2 Antibody, IgG titer is reported. Additional charges apply.
Note: If Phospholipase A2 Receptor Antibody, IgG is positive, then a Phospholipase Receptor A2 Antibody, IgG titer is reported. Additional charges apply.
Methodology:
Semi-Quantitative Indirect Fluorescent Antibody
CPT Code:
86255; if titer performed, 86256