Inhibin-B, ELISA
Label Mnemonic: INHIBB
Epic Lab Code: LAB3422
Downtime Form: A-1a Miscellaneous Request
Commercial Mail-out Laboratory
5231 RCP
356-8593
Specimen(s):
Serum
Collection Medium:
Red top tube 5 mL (Clot Activator)
Minimum:
Preferred Minimum: 0.5 mL serum
Absolute Minimum: 0.2 mL serum
Rejection Criteria:
Room temperature specimens. Hemolyzed or lipemic specimens.
Delivery Instructions:
Submit specimen to laboratory as soon as possible after collection period is completed.
Turn Around Time:
1-8 days upon receipt at reference laboratory.
Reference Range:
Males 0-6 years: 40-630 pg/mL 7-10 years: 35-170 pg/mL 11-18 years: 50-475 pg/mL 19-45 years: 40-450 pg/mL Greater than or equal to 46 years: less than 200 pg/mL Females 0-6 years less than 73 pg/mL 7-10 years less than 130 pg/mL 11-12 years less than 186 pg/mL 13-18 years less than 360 pg/mL Pre-menopausal less than 290 pg/mL Follicular phase 10-290 pg/mL Post-menopausal less than or equal to 16 pg/mL
Interpretive Data:
This test is performed using the Beckman Coulter Inhibin B ELISA kit. Values obtained with different methodologies or kits cannot be used interchangeably.
Methodology:
Quantitative Enzyme-Linked Immunosorbent Assay
CPT Code:
83520