Potassium
Label Mnemonic: | K |
Epic code: | LAB114 |
Downtime form: | Doctor/Provider Orders - Pathology Core and Specialty Care Nursery |
Chemistry
6240 RCP
356-3527
6240 RCP
356-3527
Specimen(s):
Plasma
Collection Medium:
![]() |
Plasma Separator Tube 4.5 mL |
Alternate
Collection Media:
Call laboratory for additional acceptable specimen collection containers.
Minimum:
3 mL whole blood in light green top tube or ONE
Microtainer® for pediatric patients.
Testing Schedule:
24 hrs/day, 7 days a week, including holidays.
Turn Around
Time:
1 hour (upon receipt in laboratory)
Reference Range:
3.5 - 5.0 mEq/L Pediatric Reference Ranges: Age Range Units <10 days 3.5-6.0 mEq/L >10 days 3.5-5.0 mEq/L Critical value: Adults >16 years <2.8 mEq/L and >6.2 mEq/L Pediatric (0-15 years) <3.0 mEq/L and >6.5 mEq/L
Comments:
Refer to BD Microtainer® Tubes product sheet for detailed sample collection
instructions.
Avoid hemolysis. False elevations may occur in specimens which are not processed promptly (to separate serum from RBC's). Plasma samples drawn in heparin tubes have values slightly lower than serum.
This test is also performed in the Iowa River Landing (IRL) clinical laboratory (for specimens drawn at that site).
Avoid hemolysis. False elevations may occur in specimens which are not processed promptly (to separate serum from RBC's). Plasma samples drawn in heparin tubes have values slightly lower than serum.
This test is also performed in the Iowa River Landing (IRL) clinical laboratory (for specimens drawn at that site).
Test
Limitations:
Icterus: No significant interference up to an I index of 60.
Hemolysis: Significant positive interference at an H index greater than 100 (approximate hemoglobin concentration: 100 mg/dL.
Lipemia (Intralipid): No significant interference up to an L index of 2000. There is poor correlation between turbidity and triglycerides concentration.
Hemolysis: Significant positive interference at an H index greater than 100 (approximate hemoglobin concentration: 100 mg/dL.
Lipemia (Intralipid): No significant interference up to an L index of 2000. There is poor correlation between turbidity and triglycerides concentration.
Methodology:
Ion Selective Electrode
CPT Code:
84132
See also:
Potassium-Other, Body Fluid
Potassium-Other, Body Fluid