| Carcinoembryonic Antigen | Order Code: CEA
Order Form: Laboratory Requisition |
Specimen: |
Plasma | ||
Collection Medium: |
| ||
Alternate Collection Media: |
Call laboratory for additional acceptable specimen collection containers. | ||
Minimum: |
2 ml light green top tube one 0.6 microtube (minimum) | ||
Testing Schedule: |
24 hrs/day, 7 days a week, including holidays. | ||
Analytic Time: |
1 hour (upon receipt in laboratory) | ||
Reference Range: |
*Nonsmoker: Less than or equal to 3.8 ng/ml *Smoker: Less than 5.5 ng/ml *Age 20-69 years | ||
Comments: |
Please print, complete and submit the Advance Beneficiary Notice (ABN) along with the Laboratory Requisition before shipping the specimen. | ||
Test Limitations: |
Specimens from patients who have received preparations of mouse monoclonal antibodies for diagnosis or therapy may contain human anti-mouse antibodies (HAMA). Such specimens may show either falsely elevated or depressed values. Elevations in circulating CEA levels may be observed in smokers as well as in patients with nonmalignant disease. For these reasons, a serum or plasma CEA level, regardless of value, should not be interpreted as absolute evidence for the presence or absence of malignant disease. The CEA level should be used in conjunction with information available from clinical evaluation and other diagnostic procedures. | ||
Methodology: |
Electrochemiluminescent ImmunoAssay | ||
Sample Processing: |
Centrifuge at 3000 RPM for 10 minutes. Aliquot plasma into labeled container and cap. | ||
Sample Storage: |
Refrigerate. | ||
Transport Instructions: |
Place specimen into zip-lock type bag, seal bag. Place requisition into outside pocket of bag. Transport in cooler with refrigerated coolant packs. | ||