Angiotensin-1 Converting Enzyme
Order Code: ANCE
Order Form: Laboratory Requisition
Specimen:
Plasma
Collection Medium:
Plasma Separator Tube
Alternate Collection Media:
Call laboratory for additional acceptable specimen collection containers.
Minimum:
3 mL whole blood from light green top tube or 1 microtainer for pediatric patients
Testing Schedule:
24 hrs/day, 7 days a week, including holidays.
Analytic Time:
1 hour (upon receipt in laboratory)
Reference Range:
Adults 8-52 u/l. Expected values are reported as higher in children and young adults under the age of 19 years than in older adults.
Methodology:
Kinetic Determination
Sample Processing:
Centrifuge at 3000 RPM for 10 minutes.
Aliquot plasma into labeled container and cap.
Sample Storage:
Refrigerate.
Transport Instructions:
Place specimen into zip-lock type bag, seal bag.
Place requisition into outside pocket of bag.
Transport in cooler with refrigerated coolant packs.
CPT Code:
82164
 
See also:
Angiotensin-1 Convert Enzyme-Other, Body Fluid (e.g., surgical drain, pericardial, peritoneal, peritoneal dialysis, pleural, or synovial)