University of Iowa
Diagnostic Laboratories
(UIDL) Test Directory

319-384-7212 (local)
1-866-844-2522 (toll free)


Lidocaine Order Code: LIDO
Order Form: Laboratory Requisition
Specimen:
Plasma
Collection Medium:
Plasma separator tube
Alternate
Collection Media:
Call laboratory for additional acceptable specimen collection 
containers.
Minimum:
2 ml light green top tube or 0.6 ml microtube.
Testing
Schedule:
24 hrs/day, 7 days a week, including holidays.
Analytic Time:
2 hours (upon receipt in laboratory)
Reference Range:
2-5 mcg/ml

Critical value: >5 mcg/ml
Comments:
Availability: As needed.
Methodology:
Enzyme Immunoassay
Sample
Processing:
Centrifuge at 3000 RPM for 10 minutes.
Aliquot plasma into labeled container and cap.
Sample
Storage:
Refrigerate.
Transport
Instructions:
Place requisition into outside pocket of bag.
Place specimen into zip-lock type bag, seal bag.
Transport in cooler with refrigerated coolant packs.
Instructions:
Add-on testing permitted only within 24 hours of draw time.
CPT Code:
80176
 
See Additional Information:
Chemistry Critical Lab Values

Alphabetic main page

Updated: 01/23/2008