Farmer's Lung Serology and Interpretation
| Order Code: | FARM |
| Epic Lab Code: | LAB3108 |
| Order Form: | A-1a Miscellaneous Request or Epic Req |
Commercial Mail-out Laboratory
6240 RCP
356-3527
6240 RCP
356-3527
Specimen:
Serum
Collection Medium:
![]() |
| Red top tube |
Minimum:
Adult Preferred Minimum: Two 2.5 mL aliquots of serum
from red top tube
Adult Absolute Minimum: 3 mL serum from red top tube
Pediatric Minimum: 1 mL serum from red top tube
Rejection Criteria:
Plasma. Severely lipemic, contaminated, or hemolyzed specimens.
Analytic Time:
1 week upon receipt at reference laboratory
Reference Range:
Less than 0.10 kU/L: No significant level detected
0.10-0.34 kU/L: Clinical relevance undetermined
0.35-0.70 kU/L: Low
0.71-3.50 kU/L: Moderate
3.51-17.50 kU/L: High
17.51 kU/L or Greater: Very High
Components Reference Interval
Aspergillus Fumigatus #1 None detected
Aspergillus Fumigatus #6 None detected
Aureobasidium pullulans None detected
Pigeon Serum None detected
Micropolyspora faeni None detected
Thermoactinomyces vulgaris #1 None detected
Aspergillus flavus None detected
Aspergillus fumigatus #2 None detected
Aspergillus fumigatus #3 None detected
Saccharomonospora viridis None detected
Thermoactinomyces candidus None detected
Thermoactinomyces sacchari None detected
Allergen, Fungi & Molds, Less than 0.10 kU/L: No significant
Phoma betae level detected
0.10-0.34 kU/L: Clinical relevance
undetermined
0.35-0.70 kU/L: Low
0.71-3.50 kU/L: Moderate
3.51-17.50 kU/L: High
17.51 kU/L or Greater: Very High
Allergen, Food, Beef Less than 0.10 kU/L: No significant
level detected
0.10-0.34 kU/L: Clinical relevance
undetermined
0.35-0.70 kU/L: Low
0.71-3.50 kU/L: Moderate
3.51-17.50 kU/L: High
17.51 kU/L or Greater: Very High
Allergen, Food, Pork Less than 0.10 kU/L: No significant
level detected
0.10-0.34 kU/L: Clinical relevance
undetermined
0.35-0.70 kU/L: Low
0.71-3.50 kU/L: Moderate
3.51-17.50 kU/L: High
17.51 kU/L or Greater: Very High
Allergen, Epidermals & Animal Negative
Proteins, Feather Mix
Interpretive Data:
Allergen results of 0.10-0.34 kU/L are intended for specialist use as
the clinical relevance is undetermined. Although increasing ranges are
reflective of increasing concentrations of allergen-specific IgE, this
may not correlate with the degree of clinical response or skin testing
when challenged with a specific allergen. The correlation of allergy
laboratory results with clinical history and in vivo
reactivity to specific allergens is essential. A negative test may not
rule out clinical allergy or even anaphylaxis.
Comments:
Please include relevant clinical information on test order form.
Methodology:
Immunodiffusion/ImmunoCAP®
CPT Code:
86003(x4)
86331(x12)